Notice: Undefined index: linkPowrot in C:\wwwroot\wwwroot\publikacje\publikacje.php on line 1275
Abstract: This paper presents a control system for reducing electromagnetic torque amplitude and pulsation during start-up of a three-phase induction motor. The control system is based on a new method of non-simultaneous connection of voltage phases. The effectiveness of the proposed system is shown through a simulation and an experimental verification of start-up of an squirrelcage induction motor.
B I B L I O G R A F I A[1] M. H. Rashid, Power Electronics Handbook (Academic Press, San Diego, California, 2001).
[2] M. G. Solveson, B. Mirafzal, N. A. O. Demerdash, Soft-started induction motor modeling and heating issues for different starting profiles using a flux linkage ABC frame of reference. IEEE Transactions on Industry Applications, vol. 42 n. 4, July/August 2006, pp. 973-982.
[3] Mirosevic, M., Sumina, D., Bulic, N., Influence of time gap between impact loads on torsional dynamics of generator units, (2010) International Review of Electrical Engineering (IREE), 5 (3), pp. 1012-1021.
[4] D. Torregrossa, B. Fahimi, F. Peyraut, and A. Miraoui, Fast Computation of Electromagnetic Vibrations in Electrical Machines via Field Reconstruction Method and Knowledge of Mechanical Impulse Response, IEEE Transactions on Industrial Electronics, vol. 59 n. 2, February 2012, pp. 839-847.
[5] Hooshmand, R., Azimi, M., Investigation of dynamic instability of torsional modes in power system compensated by SSSC and fixed capacitor, (2009) International Review of Electrical Engineering (IREE), 4 (1), pp. 129-138.
[6] M. H. Ali, T. Murata, J. Tamura, Effect of Fuzzy Controlled Braking Resist or on Damping Turbine Generator Shaft Torsional Oscillations During Unsuccessful Reclosing, (2006) International Review of Electrical Engineering (IREE), 1 (5), pp. 711-718.
[7] W. Paszek, Dynamics of electric alternating current machines (WNT, Warszawa 1986, in Polish).
[8] J. Staszak, Modeling the electromechanical characteristics of three-phase squirrel-cage induction motor by selection of the stator windings and the power supply system, Monography 2013, Kielce University of Technology, Poland (in polish).
[9] M. M. Sokolov, L. P. Petrov, Electromagnetic transients in an asynchronous electric motor (WNT Warszawa, 1970, in Polish).
[10] R. Nadolski, J. Staszak, K. Ludwinek, Soft-start system in alternating current electrical machines. Patent Application 395900 A1 in Poland, 2011-08-08.
[11] SimPowerSystem. For Use with Simulink. User’s Guide, Version 4 (The MathWorks, Inc., Natick, 2007).