[49450] Artykuł: A Simple Way of Determining Induced Voltages in the Damping Bars of Salient Pole Synchronous GeneratorCzasopismo: IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC) Strony: 1-4ISBN: 978-1-5090-2320-2 Wydawca: IEEE, 345 E 47TH ST, NEW YORK, NY 10017 USA Opublikowano: 2016 Autorzy / Redaktorzy / Twórcy Grupa MNiSW: Materiały z konferencji międzynarodowej (zarejestrowane w Web of Science) Punkty MNiSW: 15 Klasyfikacja Web of Science: Proceedings Paper Web of Science Keywords: damping bars  synchronous generator  FEMM  |
The article presents a simple way of determining induced voltages in the damping bars of salient pole 5.5 kVA salient pole synchronous generator under no load conditions. Field-circuital model created by coupling FEMM and Matlab environments was used for voltage calculation purposes. The simulation results were verified experimentally in the measurement stand utilizing a purpose built special rotor geometry with additional slip rings connected to individual damping bars.